Distance from riser (m) | Measured inflow rate (m3/s) | Reynold number (Re)*106 | Friction factor (f) f = 0.13/Re0.172 | Head loss (m) | Christ. factor (C) | Head loss corrected (m) |
2 6 23 81 99 | 0.002 0.0036 0.0062 0.0045 0.005 | 1.8 1.5 1.4 1.1 1.8 | 0.011 0.011 0.011 0.012 0.011 | 0.031 0.090 0.284 0.667 1.918 | 0.335 0.335 0.335 0.335 0.335 | 0.010 0.030 0.095 0.223 0.643 |